medical gas system

Tecno-Blog

What-is-a-medical-gas-outlet.

What-is-a-medical-gas-outlet.

MedikalGaz34 03/07/2020 0
...
Read More
Medikal Gaz Yoğunbakım

Medikal Gaz Yoğunbakım

MedikalGaz34 20/11/2019 0
What is Intensive Care Unit?It is used in intensive care rooms with medical gas outlets and electrical outlets and provides lighting to the room. There is a rail for medical equipment and accessories on the upper and lower parts of the front surface. It is the aluminum unit or unit where the necessary medical equipment used during medical intervention is placed on the medical gas installation equipment. About Intensive Care UnitIntensive care units are divided into Horizontal type Intensive Care Unit and Colon type (Vertical) Intensive Care Unit. In Intensive Care Patient Rooms, or in intensiv...
Read More
What is Flowmeter

What is Flowmeter

MedikalGaz34 17/11/2019 0
OXYGEN FLOWMETERWhat is Oxygen Flowmeter?It is used for humidification and filtration of oxygen gases in hospitals. It is called flow meter, flow meter or flow meter. It can provide 20 Lt / min oxygen flow. Flowmeters that are connected directly to oxygen tubes are called oxygen therapy devices. The distinguishing feature of oxygen therapy devices is that they have a regulator on the other flowmeters.   What are the Flowmeter applications and how do they work?Tecnomed Flowmeter or flowmeters can be used as central system or rail type flowmeter with hose outlet. It connects to the sockets and r...
Read More
TECHNICAL SPECIFICATIONS FOR MEDICAL GAS SOCKETS

TECHNICAL SPECIFICATIONS FOR MEDICAL GAS SOCKETS

MedikalGaz34 18/06/2019 0
TECHNICAL SPECIFICATIONS FOR MEDICAL GAS SOCKETSOXYGEN OUTLET AZOTPROTOXIDE OUTLET COMPRESSED AIR 4 BAR SOCKET COMPRESSED AIR 7 BAR SOCKET VACUUM OUTLETMedical Gas Outlets shall consist of 2 parts. Even if the first section is removed for maintenance purposes, there should be no gas leakage from the second section.Sockets should have check valve system.The sockets must be gas-specific. It should not work with the subscriber plug of another gas. Gas sockets should be in connection standard BS5682 and EN737-1 quality standard.The parts of gas sockets to be mounted on the walls or units shall be ...
Read More
TECHNICAL SPECIFICATIONS FOR MEDICAL GAS PENDANT FOR OPERATING ROOMS:

TECHNICAL SPECIFICATIONS FOR MEDICAL GAS PENDANT FOR OPERATING ROOMS:

MedikalGaz34 18/06/2019 0
TECHNICAL SPECIFICATIONS FOR MEDICAL GAS PENDANT FOR OPERATING ROOMS:ANESTHESIA PENDANT:Movable pendant arm which we call as anesthesia pendant should have the following features. The movable pendant arm should be moved approximately 600 mm with the electric motor and parked at the desired point. Moving pendant arm 90 kg. It should be capable of bearing weight. The movable pendant arm should be able to rotate 340 ° around its axis. Movable Pendant The arm must be terminated on the suspended ceiling with a square steel flange to the ceiling and with adapters that can be connected to each gas se...
Read More
INTENSIVE CARE UNIT SPECIFICATIONS

INTENSIVE CARE UNIT SPECIFICATIONS

MedikalGaz34 18/06/2019 0
COLUMN TYPE VERTICAL INTENSIVE CARE UNIT SPECIFICATIONSUpright Intensive Care Unit Ceiling to Floor Patient bed can be mounted on the right or left side. The inner frame is made of electrostatic painted sheet metal profile and the outer part should be completely covered with aluminum plate or profiles.Upright Intensive Care Unit front and back sections should be covered with flat electrostatic painted 2 mm aluminum sheets and sides should be made of aluminum round section profiles with electrostatic powder paint.The medical gas sockets must be connected to the installation in the front of the ...
Read More
WALL MOUNTED HORIZONTAL INTENSIVE CARE UNIT SPECIFICATIONS

WALL MOUNTED HORIZONTAL INTENSIVE CARE UNIT SPECIFICATIONS

MedikalGaz34 18/06/2019 0
WALL MOUNTED HORIZONTAL INTENSIVE CARE UNIT SPECIFICATIONSThe Horizontal Type Intensive Care Unit must consist of two aluminum channels with a minimum cross-section of 120x55 mm and the above-mentioned Electrical Services shall have the Medical Gas Outlets at the bottom.The main body trunks of Horizontal Type Intensive Care Unit should be connected to each other and device hanger rails made of anodized aluminum material on the top and bottom should be fixedly mounted.Medical gas outlets must be welded to the installation and exited from the unit on the right or left side of the unit.There shou...
Read More
TECHNICAL SPECIFICATIONS FOR PATIENT BED HEAD UNIT

TECHNICAL SPECIFICATIONS FOR PATIENT BED HEAD UNIT

MedikalGaz34 18/06/2019 0
TECHNICAL SPECIFICATIONS FOR PATIENT BED HEAD UNITThe Bedside Unit Medical Gas Installation and Electrical Installations must be made of extruded first quality aluminum profiles consisting of three closed sections where they can be pulled separately. The main body of the Patient Bedside Unit should have a duct at the bottom of which 95x22 mm medical gas pipes will pass and the medical gas pipes coming from the unit flow must be connected to the sockets in the unit through the opening of 80x80 mm size for the passage of these pipes. brass blocks and medical gas sockets must be connected to each...
Read More
MEDICAL GAS VACUUM REGULATOR TECHNICAL SPECIFICATIONS

MEDICAL GAS VACUUM REGULATOR TECHNICAL SPECIFICATIONS

MedikalGaz34 18/06/2019 0
MEDICAL GAS VACUUM REGULATOR TECHNICAL SPECIFICATIONS1. Endotracheal must be capable of staying at the set vacuum level. 2. Manometer and regulator. 3. It must be regulated to vacuum in the range of 0-760 mmHg. 4. Company name and gas name shall be written permanently. 5. Body shall be made of brass material and chrome plated material. 6. The Subscriber plug conforming to BS 5682: 1992 shall be mounted on it. 7. The product must be CE certified and written within the scope of the certificate. 8. Manufacturer and producer companies must have ISO 9001: 2000 quality certificate....
Read More
OXYGEN FLOWMETER TECHNICAL SPECIFICATIONS

OXYGEN FLOWMETER TECHNICAL SPECIFICATIONS

MedikalGaz34 18/06/2019 0
OXYGEN FLOWMETER TECHNICAL SPECIFICATIONSScale 1 will be incremented by 1 lpm in the 0-15 lpm range. 2. Scale Tube and Protection Glass should be made of unbreakable polycarbonate material. 3. Body Brass material should be chrome plated. 4. Company name and gas name must be written permanently. 5. The humidification bottle shall be made of unbreakable polycarbonate material. 6. The humidification bottle should be sterilizable at least 150 degrees in the autoclave. 7. Directly connected subscriber plug conforming to BS 5682: 1992 standard must be mounted on the product. 8. Manufacturer and prod...
Read More