medical gas system

Tecno-Blog

MEDICAL GAS ALARM PANEL TECHNICAL SPECIFICATIONS

MEDICAL GAS ALARM PANEL TECHNICAL SPECIFICATIONS

MedikalGaz34 18/06/2019 0
MEDICAL GAS ALARM PANEL TECHNICAL SPECIFICATIONSThe pressure in the Hospital Central Gas System will be monitored 24 hours electronically by Pressure sensors (transducers).The pressure status on the alarm panels shall be indicated by illuminated LEDs in the form of normal - high pressure and low pressure alarm conditions. When the alarm panels rise or fall below 20% above the normal working pressure or vacuum level in the installation, they will give light and audible warning signals with LEDs.Alarm panels are fully electronically controlled and must be designed as a separate electronic card f...
Read More
MEDICAL GAS FLOOR CUTTING VALVE BOX TECHNICAL SPECIFICATIONS

MEDICAL GAS FLOOR CUTTING VALVE BOX TECHNICAL SPECIFICATIONS

MedikalGaz34 18/06/2019 0
MEDICAL GAS FLOOR CUTTING VALVE BOX TECHNICAL SPECIFICATIONS1. It shall be composed of valves made of electrostatic powder coated sheet, mounted in a box.2. Valves must be spherical and full-pass and open and closed at first sight. NIST connections shall be provided with check valves which will provide gas to the related area when the valve is closed during service and maintenance periods. must be custom.3. The front cover of the valve boxes must be glazed and locked, and in an emergency, the glass should be broken and the valve accessible.4. Valves shall have welded fittings for copper pipes ...
Read More
MEDICAL TYPE COPPER PIPE INSTALLATION SPECIFICATION

MEDICAL TYPE COPPER PIPE INSTALLATION SPECIFICATION

MedikalGaz34 18/06/2019 0
MEDICAL TYPE COPPER PIPE INSTALLATION SPECIFICATIONCopper pipes according to EN 1057 World Quality and / or It should be produced according to TSE 380.There should be seamless semi-hard annealed and straight pipe.Copper should be electrolytic and free of arsenic.The inside of the copper pipes must be washed with Trichoterylene or Carbon tetrachloride. The relevant standard, the name of the manufacturer and the suitability for the use of oxygen must be permanently inscribed on the copper pipes.The copper pipes should be closed to the construction site and lowered in nylon packaging.Clamps to be...
Read More
MEDICAL AIR POWER PLANT TECHNICAL SPECIFICATIONS

MEDICAL AIR POWER PLANT TECHNICAL SPECIFICATIONS

MedikalGaz34 18/06/2019 0
MEDICAL AIR POWER PLANT TECHNICAL SPECIFICATIONSThe plant is equipped with the necessary equipment to deliver dry, clean and oil-free air to the hospital system. In case of failure of one of the central compressors, each of them shall be composed of at least two compressors, each of which shall meet the hospital needs. The connections between the Pipeline and the compressors must be made with flexible hose connections in order not to reflect the vibration in the compressor to the hospital line. The ends of the hose connections must be pressed and the connection elements at their ends must be p...
Read More
MEDICAL VACUUM PLANT TECHNICAL SPECIFICATIONS

MEDICAL VACUUM PLANT TECHNICAL SPECIFICATIONS

MedikalGaz34 18/06/2019 0
MEDICAL VACUUM PLANT TECHNICAL SPECIFICATIONS Vacuum power plant The basic elements of the central station, designed for the consumption capacity of the hospital, and the related technical specifications shall be as follows; *** The basic elements forming the central station should be composed of at least the following units. Vacuum Pumps Bacteria Filter group Vacuum Tank Electrical Control Panel with Digital Display Vacuum manometer and other fittings should be.Vacuum pumps should be designed to provide 580 mm / Hg vacuum pressure in the system with the required vacuum flow rate as a result o...
Read More
TECHNICAL SPECIFICATIONS FOR AZOTPROTOXIDE POWER PLANT

TECHNICAL SPECIFICATIONS FOR AZOTPROTOXIDE POWER PLANT

MedikalGaz34 18/06/2019 0
TECHNICAL SPECIFICATIONS FOR AZOTPROTOXIDE POWER PLANTThe system should consist of units that will send the high pressure coming from the tubes to the hospital installation by decreasing the pressure to the hospital Azotprotoxide line. At least 1 year of maintenance and 5 years fee for the system parts must be given a guarantee of availability and this guarantee must be delivered by the company to the hospital management with an official document or letter.There should be a fully automatic control panel which can be fixed in two-part place or wall mounted in the nitrogen protoxide plant. or li...
Read More
OXYGEN POWER PLANT TECHNICAL SPECIFICATIONS

OXYGEN POWER PLANT TECHNICAL SPECIFICATIONS

MedikalGaz34 18/06/2019 1
OXYGEN POWER PLANT TECHNICAL SPECIFICATIONSThe system should consist of units that will send the high pressure coming from the Tubes or Liquid Oxygen plant to the Hospital installation by reducing the pressure to the Hospital Oxygen line. At least 1 year of maintenance and 5 years fee for the system parts must be given a guarantee of availability and this guarantee must be delivered by the company to the hospital management with an official document or letter.There must be a fully automatic control panel which can be fixed in two-part place or wall mounted in the oxygen plant. The upper part o...
Read More