TECHNICAL SPECIFICATIONS FOR MEDICAL GAS SOCKETS

TECHNICAL SPECIFICATIONS FOR MEDICAL GAS SOCKETS

MedikalGaz34 18/06/2019 0
TECHNICAL SPECIFICATIONS FOR MEDICAL GAS SOCKETSOXYGEN OUTLET AZOTPROTOXIDE OUTLET COMPRESSED AIR 4 BAR SOCKET COMPRESSED AIR 7 BAR SOCKET VACUUM OUTLETMedical Gas Outlets shall consist of 2 parts. Even if the first section is removed for maintenance purposes, there should be no gas leakage from the second section.Sockets should have check valve system.The sockets must be gas-specific. It should not work with the subscriber plug of another gas. Gas sockets should be in connection standard BS5682 and EN737-1 quality standard.The parts of gas sockets to be mounted on the walls or units shall be ...
Read More
WALL MOUNTED HORIZONTAL INTENSIVE CARE UNIT SPECIFICATIONS

WALL MOUNTED HORIZONTAL INTENSIVE CARE UNIT SPECIFICATIONS

MedikalGaz34 18/06/2019 0
WALL MOUNTED HORIZONTAL INTENSIVE CARE UNIT SPECIFICATIONSThe Horizontal Type Intensive Care Unit must consist of two aluminum channels with a minimum cross-section of 120x55 mm and the above-mentioned Electrical Services shall have the Medical Gas Outlets at the bottom.The main body trunks of Horizontal Type Intensive Care Unit should be connected to each other and device hanger rails made of anodized aluminum material on the top and bottom should be fixedly mounted.Medical gas outlets must be welded to the installation and exited from the unit on the right or left side of the unit.There shou...
Read More
MEDICAL GAS VACUUM REGULATOR TECHNICAL SPECIFICATIONS

MEDICAL GAS VACUUM REGULATOR TECHNICAL SPECIFICATIONS

MedikalGaz34 18/06/2019 0
MEDICAL GAS VACUUM REGULATOR TECHNICAL SPECIFICATIONS1. Endotracheal must be capable of staying at the set vacuum level. 2. Manometer and regulator. 3. It must be regulated to vacuum in the range of 0-760 mmHg. 4. Company name and gas name shall be written permanently. 5. Body shall be made of brass material and chrome plated material. 6. The Subscriber plug conforming to BS 5682: 1992 shall be mounted on it. 7. The product must be CE certified and written within the scope of the certificate. 8. Manufacturer and producer companies must have ISO 9001: 2000 quality certificate....
Read More
OXYGEN FLOWMETER TECHNICAL SPECIFICATIONS

OXYGEN FLOWMETER TECHNICAL SPECIFICATIONS

MedikalGaz34 18/06/2019 0
OXYGEN FLOWMETER TECHNICAL SPECIFICATIONSScale 1 will be incremented by 1 lpm in the 0-15 lpm range. 2. Scale Tube and Protection Glass should be made of unbreakable polycarbonate material. 3. Body Brass material should be chrome plated. 4. Company name and gas name must be written permanently. 5. The humidification bottle shall be made of unbreakable polycarbonate material. 6. The humidification bottle should be sterilizable at least 150 degrees in the autoclave. 7. Directly connected subscriber plug conforming to BS 5682: 1992 standard must be mounted on the product. 8. Manufacturer and prod...
Read More
MEDICAL GAS ALARM PANEL TECHNICAL SPECIFICATIONS

MEDICAL GAS ALARM PANEL TECHNICAL SPECIFICATIONS

MedikalGaz34 18/06/2019 0
MEDICAL GAS ALARM PANEL TECHNICAL SPECIFICATIONSThe pressure in the Hospital Central Gas System will be monitored 24 hours electronically by Pressure sensors (transducers).The pressure status on the alarm panels shall be indicated by illuminated LEDs in the form of normal - high pressure and low pressure alarm conditions. When the alarm panels rise or fall below 20% above the normal working pressure or vacuum level in the installation, they will give light and audible warning signals with LEDs.Alarm panels are fully electronically controlled and must be designed as a separate electronic card f...
Read More
MEDICAL TYPE COPPER PIPE INSTALLATION SPECIFICATION

MEDICAL TYPE COPPER PIPE INSTALLATION SPECIFICATION

MedikalGaz34 18/06/2019 0
MEDICAL TYPE COPPER PIPE INSTALLATION SPECIFICATIONCopper pipes according to EN 1057 World Quality and / or It should be produced according to TSE 380.There should be seamless semi-hard annealed and straight pipe.Copper should be electrolytic and free of arsenic.The inside of the copper pipes must be washed with Trichoterylene or Carbon tetrachloride. The relevant standard, the name of the manufacturer and the suitability for the use of oxygen must be permanently inscribed on the copper pipes.The copper pipes should be closed to the construction site and lowered in nylon packaging.Clamps to be...
Read More
MEDICAL AIR POWER PLANT TECHNICAL SPECIFICATIONS

MEDICAL AIR POWER PLANT TECHNICAL SPECIFICATIONS

MedikalGaz34 18/06/2019 0
MEDICAL AIR POWER PLANT TECHNICAL SPECIFICATIONSThe plant is equipped with the necessary equipment to deliver dry, clean and oil-free air to the hospital system. In case of failure of one of the central compressors, each of them shall be composed of at least two compressors, each of which shall meet the hospital needs. The connections between the Pipeline and the compressors must be made with flexible hose connections in order not to reflect the vibration in the compressor to the hospital line. The ends of the hose connections must be pressed and the connection elements at their ends must be p...
Read More
MEDICAL VACUUM PLANT TECHNICAL SPECIFICATIONS

MEDICAL VACUUM PLANT TECHNICAL SPECIFICATIONS

MedikalGaz34 18/06/2019 0
MEDICAL VACUUM PLANT TECHNICAL SPECIFICATIONS Vacuum power plant The basic elements of the central station, designed for the consumption capacity of the hospital, and the related technical specifications shall be as follows; *** The basic elements forming the central station should be composed of at least the following units. Vacuum Pumps Bacteria Filter group Vacuum Tank Electrical Control Panel with Digital Display Vacuum manometer and other fittings should be.Vacuum pumps should be designed to provide 580 mm / Hg vacuum pressure in the system with the required vacuum flow rate as a result o...
Read More
TECHNICAL SPECIFICATIONS FOR AZOTPROTOXIDE POWER PLANT

TECHNICAL SPECIFICATIONS FOR AZOTPROTOXIDE POWER PLANT

MedikalGaz34 18/06/2019 0
TECHNICAL SPECIFICATIONS FOR AZOTPROTOXIDE POWER PLANTThe system should consist of units that will send the high pressure coming from the tubes to the hospital installation by decreasing the pressure to the hospital Azotprotoxide line. At least 1 year of maintenance and 5 years fee for the system parts must be given a guarantee of availability and this guarantee must be delivered by the company to the hospital management with an official document or letter.There should be a fully automatic control panel which can be fixed in two-part place or wall mounted in the nitrogen protoxide plant. or li...
Read More
OXYGEN POWER PLANT TECHNICAL SPECIFICATIONS

OXYGEN POWER PLANT TECHNICAL SPECIFICATIONS

MedikalGaz34 18/06/2019 1
OXYGEN POWER PLANT TECHNICAL SPECIFICATIONSThe system should consist of units that will send the high pressure coming from the Tubes or Liquid Oxygen plant to the Hospital installation by reducing the pressure to the Hospital Oxygen line. At least 1 year of maintenance and 5 years fee for the system parts must be given a guarantee of availability and this guarantee must be delivered by the company to the hospital management with an official document or letter.There must be a fully automatic control panel which can be fixed in two-part place or wall mounted in the oxygen plant. The upper part o...